An extension number has to be assigned to the unit and the extension number assigned to the desired group paging group(s).
Overhead paging volume may be adjusted via the volume control on the unit.
Connections are made via an RJ25 modular jack (6-pin) located on the underside of the unit.
<--- RJ25 JACK – located on the underside of the enclosure.
![]() |
PIN | DESCRIPTION | PAIR | TO |
| 1 | START LEAD | 3 | PAGING SYSTEM | |
| 2 | PAGE AUDIO | 2 | PAGING SYSTEM | |
| 3 | RING | 1 | MAGIX TDL PORT | |
| 4 | TIP | 1 | MAGIX TDL PORT | |
| 5 | PAGE AUDIO | 2 | PAGING SYSTEM | |
| 6 | START LEAD | 3 | PAGING SYSTEM |
The Magix Paging Unit is wall mounted.
4406PAG ![]() |
||
| GENERAL | Size | 10.5"L x 8.5"W x 6.25"D |
| INCLUDED ITEMS | 1ea. MA21 | Line cord, 14 foot length. 6 conductor, RJ25 modular plug on each end. |
![]() |
![]() |