Use the following PROC's only on the G2 PBX for activating queue warning indicators. These are in addition to all necessary PROC's used for the ACD activation and support.
Refer to Table 1, the system use options, for the switch settings of the QWI200.
| SW1 OPTIONS | SWITCH SETTINGS | |
|---|---|---|
| G2 Q warn | 1=open, 2=closed | |
| Factory defaults | SYS 75, G1, G3 Q warn | 1=closed, 2=closed |
The default settings of the dip switches are both closed. The switches are located on the bottom edge of the QWI200, next to the jack. Set the switches as required.

The QWI200 has keyways in the baseplate for ease of mounting. Use 2 #4 screws spaced as shown below.


The modular jack is an 8-position type, non-keyed. Terminate the cable as shown below.
A 24 volt power supply is included with the QWI200. Connect the screw terminal marked 24v+ to pin 5 of J1. Connect the 24v- terminal to pin 6 of J1.
Tip and ring provide the signal loop the QWI200 responds to. Connect the signal loop input to J1 pins 1 and 2.
The QWI200 has a visual indicator on the front. External indicators connect to J1 pins 3 and 4. The closure for external indicator allows the QWI200 to trigger other equipment (audible signals for instance) by providing a normally open relay contact closure.

---The jack numbering refers to the jack on the QWI200, not a connecting block.
---Use an 8 conductor cord.
---24 volts D.C. is required.
QWI200 ![]() |
||
| GENERAL | Size | 4.2"L X 1.65"W X 1.0"H |
| Weight | 2.5oz | |
| Operating voltage | 24vdc | |
| Power consumption | 5.6mA idle. 50mA max. | |
| INCLUDED ITEMS | 1ea. PS24.25 | power supply |
| PS24.25 POWER SUPPLY | ||
| GENERAL | Weight | 12 oz |
| Type | regulated, wall plug style | |
| Size | 2.95"L x 2.72"W x 1.93"H | |
| Operating voltage | 102-129vac, 60hz, 0.15a | |
| Output | 24vdc @ 0.25a maximum | |
![]() |
![]() |