This is a complete list of the factory settings and the input formats. You must enter the maintenance mode to change any of the following settings. You may change any or all of the settings without exiting the maintenance mode. Once you have completed your changes, press the "#" key to end your maintenance session and disconnect.
We suggest you do not attempt to change the maintenance access password until you are familiar with the operation of the CD10. If you miss-dial or forget this entry, you will no longer be able to change any of the features or messages.
PASSWORDS
Format:
Toll and local calls: [1] [1-20 digit password] #
Local calls only: [2] [1-20 digit password] #
Maintenance access: [3] [1-20 digit password] #
Factory defaults:
- 24680
- 13579
- 12345
VOICE MESSAGES
Format:
Record: [9] [message number 1-6] #
Playback: [8] [message number 1-6] #
Factory defaults:
- please enter your password
- dial the number you are calling
- please re-enter
- please wait
- you have accessed the maintenance routine
- accepted
GLOBAL SETTINGS
Format:
DIALING CODES: [0] [A,BCD,E,F,G,H] #
Factory defaults:
- A,BCD,E,F,G,H = 3**90133
This sets the CD10 for:
70ms dialing, dials 9 first with no wait, 10 digit local call, ends dialing string with #, 3 second local disconnect time, 3 second toll disconnect time.
CD10 ![]() |
||
| GENERAL | Size | 1" x 4" x 6" |
| Weight | 20 oz | |
| Operating voltage | 12vdc | |
| Power consumption | 50mA | |
| TOUCH TONES | Touch tone receive level | 0db to -32db |
| Touch tone send level | -6db | |
| Touch tone digit length | 50 to 140ms | |
| Maximum stored digits | Up to 20 | |
| VOICE | Voice message length | 1 to 6 seconds |
| Voice recording response time | 10ms max | |
| Voice output level | -25vu | |
![]() |
![]() |