The M2001 requires 24 or 48vdc power to operate. Set switch #5 for the correct operating voltage and connect the operating power to J1 pair 4. The polarity does not matter. Set option switch #5 before connecting power to J1.
A 6 watt 24 volt power supply is included with the M2001. If you are using this supply, connect the screw terminals marked 24v- and 24v+ to J1 pair 4.
The relay has 2 sets of transfer or form "c" contacts. All of the relay contacts are on J2. For simple applications, a single, normally open contact is also available on J1 pair 3. For many applications, all connections may be made with just one cable for power, input, and output.
2 lamps indicate the status of the M2001. A green idle lamp blinks when the M2001 is on, and no inputs are present. When the M2001 is active, a yellow output lamp will light, while the green lamp stops blinking and remains on.
The delay/holdover feature allows the M2001 to remain in a continuous active state with ringing, winking, or pulsing inputs. With this feature on, the M2001 remains on until no input is detected for 4.5 seconds. The M2001 will "follow" the input signal when this feature is off.
A 5 position dip switch controls the functions of the M2001. The switches are numbered from left to right, 1 to 5. When setting a switch, open=off=up, and closed=on=down.

OPTION SWITCH TABLE
INPUT TYPE
SWITCH NUMBER
1
2
3
4
5
Ring detect
OFF
OFF
n/a
ON
Ring detect with silent interval holdover
OFF
OFF
n/a
OFF
Voltage detect
ON
OFF
n/a
ON
Voltage detect with release delay
ON
OFF
n/a
OFF
Current detect
ON
ON
n/a
ON
Current detect with release delay
ON
ON
n/a
OFF
Positive logic detect
n/a
n/a
ON
n/a
Negative logic detect
n/a
n/a
OFF
n/a
24vdc operating voltage
ON
48vdc operating voltage
OFF
Factory defaults
OFF
OFF
OFF
OFF
OFF
All option switches are factory set to open.
![]() |
![]() |
![]() |