Two modular jacks, J1 & J2 are located on one end of the M2001. Power, input signals, and a normally open output all connect to J1. A complete set of DPDT contacts are available on J2. Refer to the pin-out tables for wiring.
J1 PIN-OUT
J1 PIN NUMBER
TYPE
PAIR
TYPICAL 103
OR 104 BLOCK
1
0-5vdc LOGIC
2
3
2
LOGIC COMMON
2
4
3*
NORMALLY OPEN 2
3
5
4
TIP (+)
1
2
5
RING (-)
1
1
6*
COMMON 2
3
6
7
OPERATING POWER
4
7
8
OPERATING POWER
4
8
*These contacts are common to J2 pair 2.

J2 PIN-OUT
J2 PIN NUMBER
RELAY CONTACT
PAIR
TYPICAL 103
OR 104 BLOCK
1
NORMALLY CLOSED #1
3
4
2*
COMMON #2
2
5
3
COMMON #1
1
2
4
NORMALLY OPEN #1
1
1
5*
NORMALLY OPEN #2
2
6
6
NORMALLY CLOSED #2
3
7
*These contacts are common to J1 pair 3.
Set the M2001 for the operating voltage with switch 5: open for 48vdc, closed for 24vdc. Select the type of input signal you need to detect and set switches 1 thru 4 as required. Refer to the following list or the option switch table on the previous page. Set the option switches before connecting an input to J1.
Switch 1 closed, switch 2 open, for 4.5sec release delay set switch 4 open. Connect the input voltage to J1 pair 1.
Switch 1 open, switch 2 open, for silent interval holdover set switch 4 open. Connect the input to J1 pair 1.
Switch 1 closed, switch 2 closed, for 4.5sec release delay set switch 4 open. Connect the loop to J1 pair 1.
To detect negative logic set switch 3 open. Input logic level should be 5vdc in idle state. To detect positive logic set switch 3 closed. Input logic level should be 0vdc in idle state. Connect the inputs to J1 pair 2.
The M2001 has 2 keyholes for mounting. The keyhole accepts a #4 screw. Locate the 2 screws 2.2" apart.
M2001 ![]() |
||
| GENERAL | Size | 3.0"L x 1.7"W x .75"H |
| Weight | 1.5oz | |
| Operating voltage | 24 or 48vdc | |
| Power consumption | 10ma idle / 20ma operated | |
| Detect delay | 40ms | |
| Release/holdover delay | 4.5sec | |
| Vref, for logic detect | 2.5vdc | |
| JACKS | J1 | modular, RJ48C |
| J2 | modular, RJ25C | |
| INPUTS | J1 pair 1 -Voltage detect mode | 2.5vdc minimum, 48vdc maximum |
| J1 pair 1 -Ringing detect mode | 96vac typical, 20 to 30hz | |
| J1 pair 1 -Current detect mode | 80mA maximum | |
| J1 pair 2 -Logic detect mode | 0 to 5vdc maximum | |
| J1 pair 4 -Operating voltage | 24 or 48vdc @20ma | |
| OUTPUTS | J1 pair 3 | 1 normally open dry closure (form a) |
| J2 | 2 form C dry contacts. See table above. | |
| OUTPUT DATA | Rated load | 0.5a @ 125vac, 1a @ 30vdc |
| Carry current | 1a | |
| Maximum operating voltage | 125vac, 110vdc | |
| Maximum operating current | 1 amp | |
| Maximum switching capacity | 62.5va, 33w | |
| PS24.25 SUPPLY | ||
| GENERAL | Type | regulated, wall plug |
| Size | 2.95"L x 2.72"W x 1.93"H | |
| Weight | 12oz | |
| Operating voltage | 102-129vac, 60hz, .15a | |
| OUTPUT | Voltage | 24vdc |
| Current | 0.25a maximum | |
![]() |
![]() |