Connect positive ground to pin 31. Do one of the following:
The A and B trigger inputs will operate from 10 to 48vdc. They are isolated from each other and the power to the T100. They do not have to be the same voltage or polarity.
Do one of the following:
Do one of the following:
Each timer output is a 6 pole, double throw relay with dry contacts (6 form C contacts). Refer to the tables shown and the block diagram for the pin-outs. Do not exceed the 2 amp contact rating.
T100 RELAY PIN-OUT
CIRCUIT
CONTACT
SETCOMMON
NORMALLY
OPENNORMALLY
CLOSEDA 1 3 1 5 2 4 2 6 3 10 8 12 4 11 13 9 5 16 18 24 6 19 21 17 B 1 40 44 42 2 39 37 41 3 45 43 47 4 46 50 48 5 54 56 52 6 53 55 51
Printed next to each switch is the amount of delay in seconds it represents. If a switch is on, the time is added to the total time for that circuit. If a switch is off (open) no time is added to the delay.

![]() |
![]() |
![]() |